Ratoc Systems USB-Serial Converter REX-USB60 Manuál s instrukcemi

Procházejte online nebo si stáhněte Manuál s instrukcemi pro Sítě Ratoc Systems USB-Serial Converter REX-USB60. Ratoc Systems USB-Serial Converter REX-USB60 Instruction manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 78
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Hitachi AC Servo Drive
AD Series Setup Software
AHF-P01/P02
Instruction Manual
Thank you for purchasing Hitachi AC Servo Drive Setup Software.
This instruction manual describes all the functions of Hitachi AC Servo AD
Series Setup Software AHF-P01 and furnishes the common usage
instructions for AHF-P01 and AHF-P02, excluding AHF-P02's program editor
functions. For proper software installation and use, thoroughly read this
instruction manual before using the software. For AHF-P02's program editor
functions and program operation functions, refer to the instruction manual
entitled "Hitachi AC Servo Drive Setup Software Programmable Functions".
Ensure that this instruction manual is delivered to the end user.
Read and keep this manual handy for your quick reference.
NB2711BX
Zobrazit stránku 0
1 2 3 4 5 6 ... 77 78

Shrnutí obsahu

Strany 1 - AHF-P01/P02

Hitachi AC Servo DriveAD Series Setup SoftwareAHF-P01/P02Instruction ManualThank you for purchasing Hitachi AC Servo Drive Setup Software.This instru

Strany 2 - Q NOTICES

CHAPTER 1 Installing/Uninstalling the Software1 - 44- Click the [Add/Remove Programs] icon to open the following window:In case of Windows XP, click

Strany 3 - SAFETY PRECAUTIONS

CHAPTER 1 Installing/Uninstalling the Software1 - 57- After the product disk is inserted into the floppy disk drive, click the [Next ] button.When t

Strany 4

CHAPTER 1 Installing/Uninstalling the Software1 - 610- Select an installation destination folder. To select a folder other than the default one, cl

Strany 5 - CONTENTS

CHAPTER 1 Installing/Uninstalling the Software1 - 712- The file copy process then starts.13- When the files on the first product disk are completely

Strany 6

CHAPTER 1 Installing/Uninstalling the Software1 - 815- The system needs to be updated and restarted. When the following window opens,close all the

Strany 7

CHAPTER 1 Installing/Uninstalling the Software1 - 9In case of Windows XP, to remove AHF from your PC, choose [Control Panel] fromthe menu on the tas

Strany 8 - 1.1 Preinstallation Checkout

CHAPTER 1 Installing/Uninstalling the Software1 - 101.4 Upgrade ProcedureTo upgrade the software, first uninstall the existing version of Setup Soft

Strany 9 - 1.2 Installation Procedure

2 - 1CHAPTER 2 Connecting to AD SeriesServo DriveThis section describes the cable for connecting the personal computer to the AD Series ServoDrive a

Strany 10

CHAPTER 2 Connecting to AD Series Servo Drive2 - 22. Connecting to AD Series Servo DriveQ Wiring precautionsCAUTION1. When disconnecting or connecti

Strany 11

3 - 1CHAPTER 3 Operating ProceduresThis section describes the procedures for launching and exiting the AC Servo Drive SetupSoftware, exercising its

Strany 12

Q IMPORTANTKeep this instruction manual at a place near the software operating personnel.Before installing, running, or otherwise using the software,

Strany 13

CHAPTER 3 Operating Procedures3 - 23. Operating Procedures3.1 Launching and Exiting3.1.1 Launching the software1- From the menu on the task bar, choo

Strany 14 - 1.3 Uninstallation Procedure

CHAPTER 3 Operating Procedures3 - 33.1.2 Exiting the software(1) In the case of exiting AHF1- Close all open windows except the opening window.Exit2-

Strany 15

CHAPTER 3 Operating Procedures3 - 43.2 Monitoring FunctionYou can use the monitoring function to view the operation information in real time.3.2.1 St

Strany 16 - 1.4 Upgrade Procedure

CHAPTER 3 Operating Procedures3 - 53.2.2 Description of the monitoring function windowThe figure below describes the monitoring function:Displays the

Strany 17 - Servo Drive

CHAPTER 3 Operating Procedures3 - 63.3 Parameter Setup FunctionYou can use the parameter setup function to set and manage the servo drive parameters.

Strany 18 - 2.1 Connection Cable

CHAPTER 3 Operating Procedures3 - 73.3.2 Description of the parameter setup windowThe contents of the parameter setup window are shown below: Open Sa

Strany 19

CHAPTER 3 Operating Procedures3 - 83.3.3 Editing the parametersTwo examples are presented in this section to explain about the parameter editingproce

Strany 20 - 3. Operating Procedures

CHAPTER 3 Operating Procedures3 - 93- Choose [Parameter (P)] on the menu bar and then choose [Write (W)], or click themouse on on the toolbar.4- W

Strany 21 - 3.1.2 Exiting the software

CHAPTER 3 Operating Procedures3 - 10(Example 2) Editing Fb-001- Choose the Fb tab, click the mouse on the Fb-00 setting field, and enter a newsetting

Strany 22 - 3.2 Monitoring Function

CHAPTER 3 Operating Procedures3 - 115- The following message then appears to indicate that a parameter write is inprogress.6- In case of finishing re

Strany 23

SAFETY PRECAUTIONSThe AC Servo Drive Setup Software is used to connect the Hitachi AC Servo Drive AD Series toa personal computer. It does not operat

Strany 24 - 3.3 Parameter Setup Function

CHAPTER 3 Operating Procedures3 - 12This parametercan not bechanged.NOTE 3: You cannot edit the parameters displayed in the parameter setup window if

Strany 25

CHAPTER 3 Operating Procedures3 - 133.3.4 Saving the parametersYou can save the parameters in a file for parameter management purposes.1- In the para

Strany 26 - Changed value

CHAPTER 3 Operating Procedures3 - 143.3.5 Loading the parametersA file saved in a manner described in the preceding section can be used to set up the

Strany 27

CHAPTER 3 Operating Procedures3 - 153.3.6 Reverting to factory defaultYou can revert to the factory default parameter settings. You can use this fea

Strany 28 - The edited setting

CHAPTER 3 Operating Procedures3 - 163.3.7 Printing the parametersYou can print out parameter data to compile a report.1- In the parameter setup windo

Strany 29

CHAPTER 3 Operating Procedures3 - 173.4 Operation Trace FunctionThis function enables you to visually confirm the servo drive operation. The table b

Strany 30 - This parameter

CHAPTER 3 Operating Procedures3 - 183.4.1 Starting the operation trace functionThe operation trace window opens when you click the [Trace operation (

Strany 31 - 3.3.4 Saving the parameters

CHAPTER 3 Operating Procedures3 - 193.4.2 Description of the operation trace windowThe figure below describes the contents of the operation trace win

Strany 32 - 3.3.5 Loading the parameters

CHAPTER 3 Operating Procedures3 - 203.4.3 Operation trace sequence1- Open the operation trace window.2- Perform trace setup (see the next page for th

Strany 33

CHAPTER 3 Operating Procedures3 - 213- Start an operation trace.To do this, choose [Trace operation (T)] on the menu bar and then choose [TraceStart

Strany 35 - 3.4 Operation Trace Function

CHAPTER 3 Operating Procedures3 - 225- Upon completion of data transfer, the data appears as shown below.

Strany 36

CHAPTER 3 Operating Procedures3 - 233.4.4 Operation trace setupThe trace setup window can be opened as directed below:Choose [Trace operation (T)] on

Strany 37

CHAPTER 3 Operating Procedures3 - 24(2) Digital trace setup procedure1- Check the channels to be validated (by entering a check mark in theassociated

Strany 38

CHAPTER 3 Operating Procedures3 - 253.4.5 Graph display setup(1) X-axis setup procedureWith the toolbar near a graph axis, you can enlarge the X-axis

Strany 39

CHAPTER 3 Operating Procedures3 - 26(3) Hiding a graphed lineYou can hide a graphed line by removing the associated check mark as indicatedbelow. To

Strany 40

CHAPTER 3 Operating Procedures3 - 273.5 Test Run and Adjustment FunctionsThis section describes the functions that are useful for a test run.3.5.1 Jo

Strany 41 - 3.4.4 Operation trace setup

CHAPTER 3 Operating Procedures3 - 282- Enter the speed command for jogging in field 2 below.3- Conform the safety and then click a button to specify

Strany 42

CHAPTER 3 Operating Procedures3 - 29(1-B) Pulse feed jog operation procedureIn compliance with a given position command, the pulse feed jogging opera

Strany 43 - 3.4.5 Graph display setup

CHAPTER 3 Operating Procedures3 - 30While positioning is in progress after completion of the above step, the windowlooks like the figure below:To abo

Strany 44 - Erasing all graph axes

CHAPTER 3 Operating Procedures3 - 313.5.2 Off-line tuningThe total inertia, including the motor inertia, can be approximately calculated in the off-l

Strany 45 - For entering the

CONTENTS1. Installing/Uninstalling the Software1.1 Preinstallation Checkout...

Strany 46

CHAPTER 3 Operating Procedures3 - 322- Enter the following parameters which are required for tuning:(A) Speed control cut-off frequencySet the speed

Strany 47

CHAPTER 3 Operating Procedures3 - 335- After completion of inertia estimation, the operating waveform for the last patternoperation is downloaded fro

Strany 48

CHAPTER 3 Operating Procedures3 - 34(2) Procedure for performing an off-line tuning process while verifying individualsteps1- In the opening window,

Strany 49 - Offline tuning

CHAPTER 3 Operating Procedures3 - 355- After completion of inertia estimation, the operating waveform for the last patternoperation is downloaded fro

Strany 50

CHAPTER 3 Operating Procedures3 - 363.5.3 Mechanical system diagnostic measurement procedureThe resonance point of the machine connected to the servo

Strany 51

CHAPTER 3 Operating Procedures3 - 37For AD1, click [OK] and close the Machine Diagnosis window. (AD1 series is showed as “AD series”.)For AD2, click

Strany 52

CHAPTER 3 Operating Procedures3 - 38(1) Overall setupRead the following instructions. If you are sure that your machine will remain intactand create

Strany 53

CHAPTER 3 Operating Procedures3 - 39 (e) Number (of data)You can specify the number of FFT computation points for mechanical systemdiagnostics. The

Strany 54

CHAPTER 3 Operating Procedures3 - 405- Turn on the servo ON(SON) signal.The servomotor then starts rotating. In an emergency, turn off the servo ON

Strany 55

CHAPTER 3 Operating Procedures3 - 417- The mechanical system diagnostics window opens.8- Turn off the servo ON signal, turn the RS terminal on and th

Strany 57

CHAPTER 3 Operating Procedures3 - 42NOTE: You might not be able to obtain a clean measurement result shown abovedepending on your machine no matter h

Strany 58

CHAPTER 3 Operating Procedures3 - 433.5.4 Notch filter setup procedureThe notch filter parameter can be set by performing the procedure described bel

Strany 59

CHAPTER 3 Operating Procedures3 - 443- Click the [Filter 1] button. The recommended settings are then displayed in theboxes to the right of the clic

Strany 60

CHAPTER 3 Operating Procedures3 - 453.6 Changing the Communication Format1- In the opening window, click the [Communication format (F)] button.2- Whe

Strany 61 - Line sloped downward to

CHAPTER 3 Operating Procedures3 - 463.7 Setting Motor parameters1- In the opening window, click the [Motor constants setting (I)] button. When thefo

Strany 62

CHAPTER 3 Operating Procedures3 - 473- Click the [Write Motor constants] button.It normally performs in order of “Check the output rating”, “Write M

Strany 63 - Communication

CHAPTER 3 Operating Procedures3 - 485- Click the [Servo amplifier initialization] button. As the following message is showed,click one of buttons[OK

Strany 64 - 3.7 Setting Motor parameters

CHAPTER 3 Operating Procedures3 - 49In case that unmatched motor constants against the amplifier is selected :the error occurs at the step of “Check

Strany 65

CHAPTER 3 Operating Procedures3 - 50MEMO

Strany 66

4 - 1CHAPTER 4 Troubleshooting GuideThis section furnishes the instructions for troubleshooting the product when it malfunctions orerratically opera

Strany 67

1 - 1CHAPTER 1 Installing/Uninstallingthe SoftwareThis section describes the preinstallation checkout procedure, installation procedure,uninstallati

Strany 68

CHAPTER 4 Troubleshooting Guide4 - 24. Troubleshooting Guide4.1 If the Servo Drive Cannot Be ConnectedIf the servo drive cannot be connected, procee

Strany 69

CHAPTER 4 Troubleshooting Guide4 - 34.4 If Parameter Initialization Does Not WorkIf the parameter initialization does not be work, proceed as directe

Strany 70 - 4. Troubleshooting Guide

CHAPTER 4 Troubleshooting Guide4 - 4MEMO

Strany 71

5 - 1CHAPTER 5 Appendixes5. Appendixes5.1 Files to Be Copied to System...5-25.2 Connection to a Personal Computerwithou

Strany 72

CHAPTER 5 Appendixes5 - 25. Appendixes5.1 Files to Be Copied to SystemThe table below lists the names of the files that are copied to the c:\windows

Strany 73 - CHAPTER 5 Appendixes

CHAPTER 5 Appendixes5 - 35.2 Connection to a Personal Computer without a Serial Port (RS-232C)When using the AC Servo Drive Setup Software on a pers

Strany 74 - 5. Appendixes

CHAPTER 5 Appendixes5 - 45.2.1 Connection procedures and precautions(1) Installing the PC cardInstall the PC card as directed in its documentation.

Strany 75 - CHAPTER 5 Appendixes

CHAPTER 5 Appendixes5 - 55- Although the following dialog box opens, click the [OK] button.6- Click the [Close] button.7- Connect the PC card RS-232

Strany 76

CHAPTER 5 Appendixes5 - 6MEMO

Strany 77

CHAPTER 1 Installing/Uninstalling the Software1 - 21. Installing/Uninstalling the SoftwareThe install program (SETUP.EXE) supplied on a product dis

Strany 78

CHAPTER 1 Installing/Uninstalling the Software1 - 31.2 Installation ProcedureThe following instructions presume that you install the software onto h

Komentáře k této Příručce

Žádné komentáře