5
Functions
5. Functions
(2) Procedure for setting the gain change function
1. Set the "Gain change mode" (Fd-30) to "AUto".
Set the "Position error width for gain change" (Fd-31).
The position control gain is changed based on the interrelation of "Position error
monitor" (d-09) and "Position error width for gain change" (Fd-31).
2. Set the "Second position control cut-off frequency" (Fd-32) and the "Second speed
control cut-off frequency" (Fd-34).
Default values are:
The default value for the "Second position control cut-off frequency" (Fd-32) is
double the value (10.00 [Hz]) of the "Position control cut-off frequency" (Fd-09).
The default value for the "Second speed control cut-off frequency" (Fd-34) is
double the value (60.00 [Hz]) of the "Speed control cut-off frequency" (Fd-01).
As a general guide set the Fd-32 to 1/6th or less of Fd-34.
3. After making the settings in 1 and 2 above, turn the servo on.
Note 1: A large gain difference during the gain change might cause mechanical shocks
to the machine. If that happens, set the
"Position gain change time constant"
(Fd-33) and "Speed gain change time constant" (Fd-35) to a large value (the
default value is set to 1 [ms]).
Note 2: If abnormal noise and oscillation occur during servo-lock, then set the
"Second position control cut-off frequency" (Fd-32) and the "Second speed
control cut-off frequency" (Fd-34) to a value low enough so that abnormal
noise and oscillation do not occur.