6-1
6
Parameter description
6. Parameter description
6.1 Digital operator part names and operation
6.1.1 Part names of digital operator
The RD series is operated from the built-in digital operator.
CHARGE
FUNC
SET
Function key
Shift key
Save key
Down key
Monitor indicator
(5-digit LED)
Up key
Charge lamp
Name Description
Monitor indicator Displays a monitor value or set value.
Charge lamp Lights up when charge in DC bus capacitor exceeds 30V.
FUNC
Function key Enters the monitor mode or parameter setting mode.
Shift key
Moves the indicating digit or setting digit to the left.
Pressing this key at the leftmost digit moves the selected
position to the rightmost digit.
Up key
Down key
Changes the monitor number, setup parameter number,
or parameter setting.
SET
Save key Saves parameter setting.